In previous articles about the fields of application of different pressure sensors, I have described the special top features of the various versions. Pressure range and ambient conditions are decisive when selecting a suitable sensor for an issue to be solved.
In diaphragm seal measuring ranges (e.g. < 10 bar), it is very important know whether a vented gauge pressure, non-vented gauge pressure or absolute pressure sensor is used because, with an activity pressure of 10 bar, the indication of the measured value (1.23/10 bar x 100 % = 12.3 % measurement uncertainty) moves between 8.77 bar and 11.23 bar based on the selected reference point (0 or 1 bar) and the varying ambient pressure (+/- 230 mbar).
In case of very high pressures (e.g. > 1000 bar), it is becoming less and less important to know which sensor type is used because the maximum error of just one 1.23 bar only results in a measurement uncertainty of 1 1.23 bar / 1000 bar x 100% = 0.123 %. The fields of applications described listed below are only a few selected types of the sometimes completely different fields of application of the different pressure sensors and show that, in each case, the precise accuracy requirements and ambient conditions must be considered.
Overview applications pressure sensor
More articles about this topic:
Fields of application for pressure sensors 1 ? vented digital pressure gauge of application for pressure sensors 2 ? pressure gauge -vented gauge pressure sensors
Fields of application for pressure sensors 3 ? absolute pressure sensors