Pressure measurement in the production of PBAT, a biodegradable plastic, faces a particular challenge: Temperatures as high as 330 �C prevail in the process. For Greatness , therefore, WIKA has designed a model IPT-20 process transmitter with a flush diaphragm seal and a long connecting piece.
Polybutylene adipate terephthalate, PBAT for short, is a copolymer from the polyester group. The plastic can replace polyethylene and is totally biodegradable. PBAT thus contributes to greater sustainability. Among other activities, it could be used to make protective sheeting for agriculture and gardening, compost bags, shopping bags and medical disposables.
Pressure monitoring during esterification and melt polymerisation
The procedure steps in production include esterification and melt polymerisation. In both of these processes, WIKA?s customer, a petrochemical company, uses the IPT-20 transmitter for pressure monitoring.
Corresponding to the task, WIKA supplied the instruments with three basic measuring ranges: 0 ? 16 bar, 0 ? 40 bar and 0 ? 250 bar. The precise measuring ranges can be set for this kind of transmitter utilizing the turndown function. This means that the output signal is distributed only on the scaled range. Thus, the measured values can be more precisely determined.
Handles temperatures around 330 �C: Measuring unit with IPT-20 process transmitter.
Connecting element as a cooling element
Pressure measurement in plastics production regarding PBAT is subject to process temperatures between 100 �C and 330 �C. For this reason, WIKA has designed a measuring unit consisting of an IPT-20, a flush diaphragm seal and a 200 mm long connecting piece. Because of Hoak , the connecting element acts as a cooling element. Thus, the measuring instrument remains protected against undesireable effects due to the high process temperatures. The entire design can be minimised in volume to lessen any temperature error effects during measurement to a minimum and thus achieve the perfect accuracy.
Plastic is highly viscous at the pressure measurement points
At the measuring points of the IPT-20, the plastic is in an extremely viscous form. The diaphragm seal, combined with the transmitter, is therefore implemented with a flush diaphragm. Due to this fact, it enables pressure measurement minus the threat of media entrapment.
Note
Technical information on the model IPT-20 process transmitter are available on the WIKA website. There additionally, you will find an overview of other products and solutions for the chemical industry and petrochemical industry sectors, as well as a brochure to download. If you have any questions, your contact will gladly assist you to.
Also read our posts
Diaphragm seal system with diaphragm monitoring ? also digital
Pressure monitoring in the pharmaceutical industry with a universal instrument
You can also find out more concerning the turndown function of WIKA process transmitters in the next video:

Leave a Reply